BPGNB - COBALTEC 10091

  • MSDS: BPGNB
  • Manufacturer: EUTECTIC CORP
  • Product Name: COBALTEC 10091
  • National Stock Number: 3439-00N017656
Product Identification

Product ID:COBALTEC 10091
MSDS Date:03/16/1989
FSC:3439
NIIN:00N017656
MSDS Number: BPGNB

Responsible Party
EUTECTIC CORP
40-40 172ND STREET
FLUSHING, NY 11358-9981
US

Emergency Phone: 718-358-4000

Info Phone: 718-358-4000

Cage: 72271

Contractor
EUTECTIC CORP
CHARLOTTE, NC 28273 US

Telephone: 704-527-9800/ 800-221-1433

Cage: 72271

Ingredients

TRAIN WORKER TO KEEP HIS HEAD OUT OF FUMES, GASES,

RTECS: 9999999ZZ


ARM PROTECTORS, APRONS, HATS, SHOULDER

RTECS: 9999999ZZ


COBALT

CAS: 7440-48-4

RTECS: GF8750000

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


CHROMIUM

CAS: 7440-47-3

RTECS: GB4200000

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


NICKEL

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


TUNGSTEN

CAS: 7440-33-7

RTECS: YO7175000

OSHA PEL 5 MG/M3;10 STEL

ACGIH TLV: 5 MG/M3;10 STEL


IRON

CAS: 7439-89-6

RTECS: NO4565500

OSHA PEL 10 MG/M3

ACGIH TLV: 5 MG/M3


BORON

CAS: 7440-42-8

RTECS: ED7350000

OSHA PEL 15 MG/M3 (AS OXIDE)

ACGIH TLV: 10 MG/M3 (AS OXIDE)


SILICON

CAS: 7440-21-3

RTECS: VW0400000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


CHROMIUM CMPDS HAVE AN EXCESS OF LUNG CANCERS.

RTECS: 9999999ZZ


CARCIN. ABSORP OF CHROMIUM (VI) CMPDS THRU SKIN CAN

RTECS: 9999999ZZ


GOOD PRACT REQS REDUCTION OF EMPLOYEE EXPOS TO

RTECS: 9999999ZZ


CMPDS MAY CAUSE LUNG FIBROSIS OR PNEUMOCONIOSIS.

RTECS: 9999999ZZ


INCIDENCE OF LUNG & NASAL CANCERS. NICKEL & CMPDS

RTECS: 9999999ZZ


IARC STATES SPECIFIC NICKEL CMPDS THAT MAY BE CARCIN

RTECS: 9999999ZZ


AND BURN SKIN.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE OVEREXP TO FUMES, GASES/DUSTS
MAY RSLT IN DISCOMFORT SUCH AS DIZZ, NAUS, OR DRYNESS/IRRIT OF
NOSE, THROAT/EYES. ING 7: POSS EYE IRRIT. ING 2: INHAL OF FUME
W/CHROMIUM (VI) CMPDS CAN CAUSE IRRIT OF RESP SYS, DMG TO LUNGS,&
ASTHMA LIKESYMP. SWALLOWING CHROMIUM (VI) SALTS CAN CAUSE SEV
INJ/DEATH. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL: GROUP 2B (IARC), ANTICIPATED TO
BE A CARCIN (NTP); COBALT AND COBALT COMPOUNDS
Effects of Overexposure:HLTH HAZ:DUSTS ON SKIN CAN FORM ULCERS.EYES MAY
BE BURNED BY CHROMIUM (VI) CMPDS. ALLERGIC RXNS LIKELY IN SOME
PEOPLE FROM CHROMIUM CMPDS.ING 3: METALLIC TASTE, NAUS, TIGHTNESS
IN CHEST, FEVER, ALLERG IC RXNS. CHRONIC OVEREXP TO FUMES, GASES,&
DUSTS MAY LEAD TO SIDEROSIS (IRON DEPOSITS IN LUNGS)& MAY AFFECT
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER . EYES: FLUSH WITH
WATER FOR AT LEAST 15 MINUTES. CALL MD . INGESTION: CALL MD
IMMEDIATELY . INHALATION: REMOVE FROM EXPOSURE. SUPPORT BREAT HING
(GIVE ARTIFICIAL RESPIRATION/OXYGEN) . REMOVE TO WELL VENTILATED
AREA. CALL FOR MEDICAL AID. EMPLOY FIRST-AID TECHNIQUES RECOMMENDED
BY AMERICAN RED CROSS.

Fire Fighting

Flash Point:NONFLAMMABLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:METAL POWDER DUST MAY PRESENT FIRE/EXPLO
HAZ UNDER FAVORABLE CNDTNS OF PARTICLE SIZE,DISPERSION & STRONG
IGNIT SOURCE.REFER TO AWS C2.1 " RECOM SAFE (SUPP DATA)

Accidental Release

Spill Release Procedures:CLEAN-UP BY VACUUMING, WET DUSTMOP, OR WET
CLEAN-UP. AVOID DUST GENERATION. USE AN APPROP FILTER W/VACUUM
EQUIP TO PVNT AIRBORNE DUST LEVELS WHICH EXCEED PEL/TLV. IF
AIRBORNE DUST IS GENERATED, USE AN APPROP NIOSH/MSHA APPRVD RESP
DURING CLEAN-UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:MAINTAIN EXPOSURE BELOW GIVEN PEL/TLV. USE INDUSTRIAL
HYGIENE MONITORING TO ENSURE THAT USE OF THIS PRODUCT DOES NOT
CREATE EXPOSURE EXCEEDING PEL/TLV. REFER TO GIVEN REFERENCES FOR
ADDITIONAL INFORMA TION.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATOR OR AIR SUPPLIED RESPIRATOR WHEN WORKING IN CONFINED OR
WHERE LOCAL EXHAUST OR VENTILATION DOES NOT KEEP EXPOSURE BELOW
RECOMMENDED EXPOSURE LIMIT.
Ventilation:USE ENOUGH GEN VENT & LOC EXHST AT WORK SITE TO KEEP
FUMES,GASES & DUSTS FROM WORKER'S BRTHG ZONE & GEN AREA. (ING 15)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG/FULL LGTH FACESHLD .
Other Protective Equipment:WEAR HAND, HEAD, & BODY PROD WHICH HELP PVNT
INJ FROM RADIA, & FLAMES. SEE ANSI Z49.1. AT MIN, THIS MAY INCL
(ING 16)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: PRACT FOR THERM SPRAYING" FOR MORE DETAIL. HAZ DECOMP PRODS:
RXN PRODS MAY INCL CO & CO*2. OZONE & NO*X MAY BE FORMED BY RADIA.
EFTS OF OVEREXP: PULM FUNCT. ING 7: OVEREXP TO AMORPHOUS SILI CA
CAN CAUSE PNEUMOCONIOSIS. ING 2: STUDIES HAVE SHOWN THAT CHROMATE
PRODUCTION WORKERS EXPOS TO HEXAVALENT (ING 8)

Chemical Properties

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:REASONABLY EXPECTED CONSTITUENTS OF
FUME WOULD INCL COMPLEX OXIDES OF METALS LISTED IN ING SECTION.
GASEOUS (SUPP DATA)

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR
LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
WITH FEDERAL, STATE, A ND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.